Power Timer (Model TMR-30KE P/N 390-0030-5)

Dec. 31, 2012

The Kussmaul Power Timer, Model TMR-30KE P/N 390-0030-5, eliminates dead batteries caused by power drain from radios and data terminals that operate while the engine is off. The unit allows the use of accessory loads per programmed time limit while preserving the battery for starting the engine.

The Power Timer is programmable, ensuring adequate reserve to start the engine. Rugged construction, powder coated case with epoxy coated components, and water proof time-out setting switches, the unit is designed to withstand 80°C and the vibration of the engine compartment. The 30 amp rating permits powering multiple auxiliary loads/circuits without running the engine.

Features

  • Programmable disconnect time limit, 15 minutes to 8 hours, so that you can match your auxiliary load use to battery capacity, providing maximum run time yet still ensuring adequate reserve for engine start
  • Prevents dead batteries due to accessories being left on and forgotten
  • Once power off circuit is activated, power to auxiliary circuits is automatically restored when the engine is started. Optional ignition sense input resets power ‘on’ without having to start engine; no delay in use of equipment
  • Low and High Voltage Disconnect
  • Simple 3 wire installation:1) power in from battery 2) power out to loads 3) chassis ground
  • Rugged construction, powdered coated case with epoxy potted components with waterproof time-out setting switches. Designed to withstand 80° C and the vibration of engine compartment applications, and perform in demanding emergency vehicle applications
  • 30 amp rating: can be applied to multiple auxiliary loads/circuits. Multiple devices can be left on during emergency calls without running the engine

Timer Circuit Configurations

  • Range: 15 min - 8 hours
  • Increments: Minutes: 6, 15, 18, 24, 30, 45
  • Hours: 1, 1.5, 2, 3, 4, 8
  • Programming: Dip switches on top of unit

Specifications

  • Rating: 12 volt nominal, 30 amps, 13 mA standby current
  • Protection: Low and high voltage disconnect
  • Low < 10.5V with 10 second delay
  • High > 15.0V with 3 second delay
  • Operating Temperature: -20 to +80° C

Mechanical

  • Case: Powder coated steel with epoxy potted components
  • Size: (H x W x D): 1.25” x 4.25” x 2”
  • Weight: 1Lb.

LED’s Indicate Output Status

  • Present, Ok
  • Present, On Timer
  • Disconnected, Timed Out
  • Disconnected, Low Voltage Wiring

Input

  • + DC (fuse provided)
  • – DC
  • Ignition sense 

Ouput

  • + DC to loads

Request More Information

By clicking above, I acknowledge and agree to Endeavor Business Media’s Terms of Service and to Endeavor Business Media's use of my contact information to communicate with me about offerings by Endeavor, its brands, affiliates and/or third-party partners, consistent with Endeavor's Privacy Policy. In addition, I understand that my personal information will be shared with any sponsor(s) of the resource, so they can contact me directly about their products or services. Please refer to the privacy policies of such sponsor(s) for more details on how your information will be used by them. You may unsubscribe at any time.